What was found
FWD CARGO DOOR LOWER AFT CORNER EDGE BEAM HAS CHAFING AND GOUGE. REMOVED CHAFING IAW SRM 52-30-02. CHECKED LIMITS AND FOUND OUT OF LIMITS IAW SRM 52-30-02, FIG. 101, DETAIL 1 & 2; BEFORE: .050", AFTER: .037", LOSS: .017". REMOVED LOWER AFT CORNER IAW SRM 51-40-02. RECEIVED NEW CORNER ON BATCH NR 0002125683. INSTALLED NEW LOWER CORNER EDGE BEAM IAW SRM 51-40-02, AND DWG 654N0244, AT FWD CARGO DOOR LOWER AFT CORNER. MAJOR REPAIR.