What was found
FLOOR SEAT TRACK 2L, AREA OF PANEL LANDING CORRODED AT FR54. FOUND TO BE OUT OF LIMITS IAW SRM 53-10-16, FIG 102, PG 105. R & R SEAT TRACK FROM FRAME 45 TO FRAME 54 IAW SRM 51-72-10, PARA 1-6, PG 1- 3 WITH NEW SEAT TRACK FABRICATED IAW AB DWG A538322112. ORIGINAL SUBMISSION DATE: 12/01/2011