What was found
SEAT TRACK 2R HAS CORROSION BETWEEN FR 40 & FR 45. DEFFECT MEASURES 8 SQ INCHES. AFTER REMOVING LEVEL 1 CORROSION FROM SEAT TRACK IAW SRM 51-11-10 PAR 3, MATERIAL LOSS AND LIMIT CHECKED IAW SRM 51-74-10. FOUND TO BE OUT OF LIMITS. REMOVED SEAT TRACK IAW SRM 51-40-21. LOCATED AND DRILLED IAW SRM 51-40-44 PAR 2, TABLE 3. REPROTECTED IAW SRM 51-21-10 AND 51-75-10. INSTALLED IAW SRM 51-40-21, PAR 6 TO 7.