What was found
UPON REMOVAL OF SEALANT FROM BUTTJOINT FOUND VERTICAL SCRIBE LINE ON BUTT JOINT STRAP SURFACE AT BS 1621 FROM APPROX S-14L, THROUGH S-16L. HFEC INSPECTION OF SCRIBE LINE IAW NDTM53-30-09, NO CRACKS NOTE. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-01, DETAIL 5, FIG 101, SHEET 6. REMOVED BUTT SPLICE IAW SRM 51-40-02. FABRICATED NEW BUTT SPLICE IAW DWG 146N3700. INSTALLED NEW BUTT SPLICE, IAW SRM 51-40-02, AND DWG 146N3700. MAJOR REPAIR (CAT. "A")