What was found
AFTER REMOVAL OF FLOOR SUPPORT AT STA 1500, RBL 2.50 FOUND CORROSION ON FRAME IN AFT CARGO PIT. REMOVED CORROSION AT FRAME IAW SRM 51-10-02. BLENDED AREA. ORIGINAL MATERIAL .063, MATERIAL LOSS .033, MATERIAL REMAINING .030. FOUND OUT OF LIMITS IAW SRM 53-00-07, FIG 101, DETAIL II. R & R FRAME. MAJOR REPAIR.