What was found
FRAME 21 HAS A .25 DRILL START BETWEEN STRINGERS 8R & 9R. CUTOUT DAMAGED SECTION OF FRAME AND SPLICED IN NEW SECTION IAW EA 6-5310-156080.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME 21 HAS A .25 DRILL START BETWEEN STRINGERS 8R & 9R. CUTOUT DAMAGED SECTION OF FRAME AND SPLICED IN NEW SECTION IAW EA 6-5310-156080.