What was found
FLOOR PRESSURE WEB BETWEEN SEAT TRACK 2L - 3L AT FR 26 HAS SURFACE CORROSION AT 3 LOCATIONS. REMOVED CORROSION FROM FLOOR PRESSURE WEB BETWEEN SEAT TRACK 2L - 3L AT FR 26, ORIGINAL THICKNESS OF MAT. IS .071", MAX MATERIAL REMOVED .018" ; FOUND TO BE OUT OF LIMITS IAW STANDARDS MANUAL. REMOVED PRESSURE WEB IAW SRM 51-40-21, FABRICATED PANEL, LOCATED, DRILLED, DEBURRED IAW SRM 51-40-44 AND DWG A53781984. ALODINED PANEL IAW SRM 51-21-10, PRIMED AND PAINTED PANEL IAW SRM 51-75-10. INSTALLED PANEL IAW SRM 51-40-21. PART MARKED IAW GMM 7-1-101.