What was found
DURING X-RAY INSPECTION, FOUND ONE CRACK AT STA 5-123 TRANSVERSE SKIN SPLICE LONGERON 6L ON THE AFT SIDE CTR OF THE SPLICE FROM AFT EDGE TO NR 4 FASTENER HOLE. R & R IAW SRM 51-33-01, REV 48, FABRICATED IAW DWG, REV E. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100, REV 113.