What was found
RT BS 1229 XCW = -80 XCW X=-85 CENTER WING UPPER PANEL FOUND CORROSION. CORROSION REMOVED IAW SRM 51-21-00, REV 48, ORIGINAL MATERIAL THICKNESS=0.177" REMAINING THICKNESS = 0.112" MATERIAL REMOVED =0.065" AND FOUND ACCEPTABLE IAW EA 1-5730-154278. REPAIR CLASSIFIED MINOR IAW GMM 6-2-100, REV 113.