What was found
CREASE BEAM AT STRINGER 17R BS 1620-1630 CORRODED. REMOVED CORROSION IAW SRM 51-10-02, CHECKED LIMITS ORIG MAT .080, BLENDED MAT .018, REMAINING MAT .062. FOUND OUT OF LIMITS IAW SRM 53-60-13, FIG 101 DET VIII. REMOVED CREASE BEAM SECTION IAW SRM 51-40-02. FABRICATED USING BAC 1515-553, IAW 53-60-13. INSTALLED IAW 51-40-02 AND DWG 146N8722 AT STA 1410 TO STA 1630. MAJOR REPAIR.