What was found
MDCC FLOOR THRUST PLATE BETWEEN FR 26 AND FR27 AND -Y450 TO -Y 953 (SEAT TRACK 2R AND 3R), HAS .5 INCH OF CORROSION. THRUST PLATE FOUND TO BE OUT OF LIMITS IAW DWG A53781984. R & R THRUSTPLATE IAW SRM 51-40-21, PARA 5 AND DWG A53781984.