What was found
LEFT WING, WING SIDE OTBD FLAP INBD HINGE LOWER MOUNT AFT SURFACE FOUND CORROSION. REPAIRED IAW EA 1-5750-76665A PART 2, STEP 3 AND 4. OTBD AFT EXISTING THICKNESS :0.439", MATERIAL REMOVED 0.015", REMAINING THICKNESS 0.424". INBD AFT EXISTING THICKNESS :0.409', MATERIAL REMOVED 0.025" REMAINING THICKNESS 0.384'. MINIMUM ALLOWABLE THICKNESS 0.423". REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100, REV 114.