What was found
BS 1681.8 TO 1720 AT BL 0 TO LBL 60 CABIN FLOOR SHEAR WEB HAS CORROSION. BLENDED AREAS IAW SRM 51-10-02. CHECKED LIMITS FOUND TO BE OUT OF LIMITS IAW SRM 53-60-51, FIG 201, SH. 1. REMOVED CABIN FLOOR WEB, IAW SRM 51-40-02. FABRICATED NEW SHEAR WEB IAW SRM 51-10-02, SRM 53-60-51, FIG 1, DETAIL III, AND DWG 146N 5318. INSTALLED NEW WEB IAW SRM 51-40-02, AND DWG 146N5318. MAJOR REPAIR.