What was found
DURING VISUAL INSPECTION OF LT FWD CREW/COURIER DOOR AT LWR AFT CORNER RADIUS FAILSAFE RING, 1 SQ IN PITTED CORROSION FOUND. AFT CORNER FITING FOUND TO BE OUT OF LIMITS IAW DWG A53611556. R & R FITTING IAW SRM 51-40-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING VISUAL INSPECTION OF LT FWD CREW/COURIER DOOR AT LWR AFT CORNER RADIUS FAILSAFE RING, 1 SQ IN PITTED CORROSION FOUND. AFT CORNER FITING FOUND TO BE OUT OF LIMITS IAW DWG A53611556. R & R FITTING IAW SRM 51-40-21.