What was found
CABIN FLOORBEAM BS 365.25, BL 0 - RBL 61, UPPER TEE CORRODED. REMOVED CORROSION, ORIGINAL MATERIAL .125", REMOVED .090", FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, FIG 101, SHEET 4, DETAIL 3. REPAIRED FLOORBEAM AT BS 365.25, BL 0 - RBL 61, IAW SRM 53-00-51, FIG 101, PAGE 204, DETAIL 1 AND FIG 201, SHEET 5. MAJOR REPAIR.