What was found
AFT CARGO BAY, STA 1380 STR 29L-29R, FRAME LOWER CHORD CORRODED. REMOVED CORROSION ORIG MAT .090 AFTER REWORK MAT WAS .061 WITH MATERIAL LOSS OF .029 FOUND TO BE OUT OF LIMITS IAW SRM 53-00-07, FIG 101, DETAIL 2. INSTALLED FAILSAFE AND TWO VERTICAL SUPPORTS IAW SRM 51-40-02 AND DWG 146N1010.