What was found
RT WING OTBD FLAP, OTBD FWD HINGE BRACKET SIDE LOAD FITTING ATTACH SURFACE FOUND CORRODED. AREA REWORKED IAW CMM 57-44-09, REV 72. EXISTING THICKNESS UPPER 0.406", LOWER 0.406", REMAINING THICKNESS UPPER 0.400", LOWER 0.400". REPAIRED IAW EA 1-5750-157158 PART 1, STEPS 1, 2, 3, AND 6. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100 REV 114.