What was found
LEFT WING OTBD FLAP, INBD FORWARD HINGE BRACKET SIDE LOAD FITTING ATTACH SURFACE FOUND CORRODED. SURFACE REWORKED IAW REV 72. EXISTING THICKNESS UPPER 0.356", LOWER 0.355", REMAINING THICKNESS UPPER 0.353", LOWER 0.354". MATERIAL REMOVED: UPPER 0.002", LOWER 0.002". CARRIED OUT IAW EA 1-5750-157159 PART 1STEPS 1, 2, 3, AND 6. REPAIR CLASSIFIED AS MAJOR GMM 6-2-100, REV 114.