What was found
RT INBD CREASE BEAM ANGLE CORRODED AT BS 1630. REMOVED CORROSION IAW SRM 51-10-02. CHECKED LIMITS, FOUND TO BE OUT OF LIMITS IAW SRM 53-60-13, FIG 101, DETAIL VIII. FABRICATED, ALODINED, PRIMED IAW SRM 51-20-01 AND INSTALLED IAW SRM 51-40-02, AND DWG 146N8722. MAJOR REPAIR.