What was found
L1 DOOR PRESS TO TEST SWITCH FOR EVACUATION SLIDE BOTTLE PRESSURE CHECK, INOPERATIVE. FOUND NO POWER BEFORE SWITCH. R & R BATTERIES, PERFORMED TEST, LIGHT COMES ON IAW MM 25-61-15-4. OPS CHECKED OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
L1 DOOR PRESS TO TEST SWITCH FOR EVACUATION SLIDE BOTTLE PRESSURE CHECK, INOPERATIVE. FOUND NO POWER BEFORE SWITCH. R & R BATTERIES, PERFORMED TEST, LIGHT COMES ON IAW MM 25-61-15-4. OPS CHECKED OK.