What was found
FLOORBOARD 231GG TOP PLY HAS SESVERAL PUNCTURES (BB) AND AN 8 INCH LONG CRACK AT LT EDGE APPROX 26" FWD OF AFT EDGE, ALL INSERTS ARE CORRODED ON LWR SURFACES AND EDGE FILLER IS MISSING FROM ALL SIDES AND CUTOUT. FABRICATED FLOORBOARD IAW DWG SRZ 25-005, REV J.