What was found
FOUND KNIFE EDGE CHAFING ON LOWER END OF SUPPORT ON VERTICAL STAB. R & R WITH FAIRING SUPPORT FABRICIATED IAW DWG 173N1300-3, SHT 1, REV B AND INSTALLED IAW DWG 173N1300 SHT 1, REV B. REPAIR IS CLASSIFIED AS MAJOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND KNIFE EDGE CHAFING ON LOWER END OF SUPPORT ON VERTICAL STAB. R & R WITH FAIRING SUPPORT FABRICIATED IAW DWG 173N1300-3, SHT 1, REV B AND INSTALLED IAW DWG 173N1300 SHT 1, REV B. REPAIR IS CLASSIFIED AS MAJOR.