What was found
FLOORBEAM AT BS 128, LBL 27 CORRODED. R & R WITH FABRICATED FLOORBEAM IAW SRM 51-40-02. REV 105 AND DWG 146N5005, SHT 1, REV A. REPAIR IS CLASSIFIED AS MAJOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM AT BS 128, LBL 27 CORRODED. R & R WITH FABRICATED FLOORBEAM IAW SRM 51-40-02. REV 105 AND DWG 146N5005, SHT 1, REV A. REPAIR IS CLASSIFIED AS MAJOR.