What was found
RT WING (WING SIDE) OTBD FLAP, INBD HINGE LOWER MOUNT OTBD HOLE, FOUND CORRODED. BUSHING REMOVED IAW CMM 20-20-07, REV 72. LOWER MOUNT OTBD BORE REWORKED AND FOUND EXCEED LIMIT IAW CMM 57-44-08, REV 72. EXISTING BORE DIAMETER 0.708", FINAL BORE DIAMETER 0.708", MAXIMUM ALLOWABLE DIAMETER 0.709". REPAIR ACCOMPLISHED IAW EA 1-5750-160028 PART 1, STEPS 2, 5, 7 AND 8. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 114.