What was found
EMPENNAGE RT SIDE THE APU INLET FWD EDGE NUTPLATE STRAP HAS CORROSION AT BS 1790 BETWEEN STR 4 - 7 RT. R & R IAW DWG 148N3105, SHT 1 REV C. REPAIR IS CLASSIFIED AS MAJOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMPENNAGE RT SIDE THE APU INLET FWD EDGE NUTPLATE STRAP HAS CORROSION AT BS 1790 BETWEEN STR 4 - 7 RT. R & R IAW DWG 148N3105, SHT 1 REV C. REPAIR IS CLASSIFIED AS MAJOR.