What was found
EMPENNAGE, APU INLET MOUNTING AREA AT BS 1790 - 1823 STR 7R THE NUTPLATE ATTACH ANGLE CORRODED. REMOVED, & FABRICATED IAW DWG 148N3152 SHT1, REV - INSTALLED IAW SRM 51-40-02, REV 105. REPAIR IS CLASSIFIED AS MAJOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMPENNAGE, APU INLET MOUNTING AREA AT BS 1790 - 1823 STR 7R THE NUTPLATE ATTACH ANGLE CORRODED. REMOVED, & FABRICATED IAW DWG 148N3152 SHT1, REV - INSTALLED IAW SRM 51-40-02, REV 105. REPAIR IS CLASSIFIED AS MAJOR.