What was found
EMPENNAGE, APU INLET AREA AT BS 1790 - 1823 STR 4 R THE NUTPLATE ATTACH ANGLE CORRODED. R & R WITH NUTPLATE ANGLE FABRICATED IAW DWG 148N3152, SHT 1 REV AND INSTALLED IAW SRM 51-40-02, REV 105. REPAIR IS CLASSIFIED AS MAJOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMPENNAGE, APU INLET AREA AT BS 1790 - 1823 STR 4 R THE NUTPLATE ATTACH ANGLE CORRODED. R & R WITH NUTPLATE ANGLE FABRICATED IAW DWG 148N3152, SHT 1 REV AND INSTALLED IAW SRM 51-40-02, REV 105. REPAIR IS CLASSIFIED AS MAJOR.