What was found
BS 1681 FLOORBEAM CORRODED ON BOTTOM OF LOWER FLANGE LBL 58. REMOVED CORROSION IAW SRM 51-10-02. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51 PG 104, FIG 101, DETAILS 2 AND 3. R & R FLOORBEAM IAW SRM 51-40-02 AND DWG 146N5091.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 1681 FLOORBEAM CORRODED ON BOTTOM OF LOWER FLANGE LBL 58. REMOVED CORROSION IAW SRM 51-10-02. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51 PG 104, FIG 101, DETAILS 2 AND 3. R & R FLOORBEAM IAW SRM 51-40-02 AND DWG 146N5091.