CORROSION ON FLOOR CHANNEL RBL 63, STA 1348. REMOVED CORROSION IAW SRM 51-10-02, ORIG MATERIAL .100, REMAINING .050. FOUND TO BE OUT OF LIMITS IAW SRM 53-30-13, DETAIL II, FIG 101. R & R INBD CHANNEL IAW SRM 51-40-02. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOOR CHANNEL RBL 63, STA 1348. REMOVED CORROSION IAW SRM 51-10-02, ORIG MATERIAL .100, REMAINING .050. FOUND TO BE OUT OF LIMITS IAW SRM 53-30-13, DETAIL II, FIG 101. R & R INBD CHANNEL IAW SRM 51-40-02. MAJOR REPAIR.