What was found
FLOORBEAM BS 740 LBL 14 UPPER TEE CORRODED. FLOORBEAM FOUND OUT OF LIMITS IAW SRM 53-00-1, FIG 101, DETAIL II AND III. ORIGINAL MATERIAL .125 AFTER REWORK .070. R & R FLOORBEAM IAW SRM 51-40-02 AND DWG 143N5016, SH 5. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM BS 740 LBL 14 UPPER TEE CORRODED. FLOORBEAM FOUND OUT OF LIMITS IAW SRM 53-00-1, FIG 101, DETAIL II AND III. ORIGINAL MATERIAL .125 AFTER REWORK .070. R & R FLOORBEAM IAW SRM 51-40-02 AND DWG 143N5016, SH 5. MAJOR REPAIR.