What was found
MAIN DECK CARGO FLOOR THRUST BRACKET AFT OF FR 25 BETWEEN SEAT TRACKS 5R & 6R UPPER SURFACE CORRODED 2 SQUARE INCHES (LOCATION FR 25 3 INCHES). REMOVED CORROSION FROM THRUST PLATE BETWEEN FR25 AND FR 26, BETWEEN SEAT TRACKS 5R AND 6R IAW SRM 51-74-10. FOUND BLENDED OUT AREA OUT-OF-TOLERANCE IAW SRM 51-73-10, PG1 AND ABS 5044, PG 5. FABRICATED THRUST PLATE IAW DWG A53781984. R & R THRUST PLATE IAW FSRM 51-72-10. PROTECTED AREAS AND PARTS IAW SRM 51-74-10.