What was found
APPROX STA 755 RT INBD CREASE BEAM CHORD CORRODED. REMOVED CORROSION IAW SRM 51-10-02, CHECK LIMITS AND FOUND TO BE OUT OF LIMITS IAW SRM53-30-13, FIG 101, DET VII. REMOVED CREASE BEAM IAW SRM 51-40-02, FABRICATED CREASE BEAM FROM BAC1515-553 IAW SRM 53-30-13 AND SRM 51-40-05 AND INSTALLED CREASE BEAM IAW SRM 51-40-02.