What was found
MAIN DECK CARGO FLOORBOARD 241WH HAS FIVE CRACKS FROM 4 TO 8 INCHES LONG AT CLEVIS CUTOUTS. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK CARGO FLOORBOARD 241WH HAS FIVE CRACKS FROM 4 TO 8 INCHES LONG AT CLEVIS CUTOUTS. FABRICATED REPLACEMENT FLOORBOARD IAW DWG SRZ 25-005, REV J.