What was found
LT WING OTBD FLAP, OTBD FORWARD HINGE BRACKET ACTUATOR ATTACH INBD LUG BORE SPOT FACE FOUND CORRODED. REWORKED AND FOUND EXCEED LIMIT IAW CMM 57-44-09 REV 72. EXISITING THICKNESS 0.321", REMAINING THICKNESS 0.318", MATERIAL REMOVED 0.003", MINIMUM ALLOWABLE THICKNESS 0.320". REPAIR CARRIED OUT IAW EA 1-5750-157176. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 114.