What was found
RIGHT MAIN DECK CARGO FRAME 24, BENT AT SPLICE AND MISSING ONE FASTENER BETWEEN STR 8R AND 9R DEFECT MEASURES 2.5 INCHES LONG. AFTER REMOVAL OF FASTENERS AND REFORMING BENT SPLICE IAW SRM 51-40-21, AND SRM 51-26-00 PG 1, NDT VERIFIED A 2 INCH CRACK IN PREVIOUSLY REPAIRED FRAME SPLICE SECTION. (NOT ON FRAME) FABRICATED REPAIR PARTS AND INSTALLED IAW SRM 51-72-10 AND DWG 13 A537 70435 .