What was found
FOUND FEEDER CABLE AT STA 1481 ARCED ON FLOORBEAM. R & R IAW SWPM 20-20-01, REV 26.0 AND AMM 20-30-10-2, REV 72.0 WIRING CONTINUITY CHECK CARRIED OUT IAW WDM 24-22-11, REV 74.0 FOUND SATISFACTORY. APU OPS TEST CARRIED OUT IAW AMM 49-10-00-2, REV 72.0 AND NICKEL CADMIUM BATTERY OPS TEST CARRIED OUT IAW AMM 24-34-02-700-802, REV 72.0 FOUND SATISFACTORY. REPAIR CLASSIFIED MINOR IAW GMM 6-2-100, REV 114.