What was found
FRAME AT BS 660, BETWEEN S24R AND S25R HAS DENT IN UPPER FLANGE, FOUND TO BE OUT OF LIMITS IAW SRM 53-30-07, FIG 101, SH 1. REMOVED AND INSTALLED NEW FRAME IAW SRM 51-40-02 AND DWG 143N1024. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME AT BS 660, BETWEEN S24R AND S25R HAS DENT IN UPPER FLANGE, FOUND TO BE OUT OF LIMITS IAW SRM 53-30-07, FIG 101, SH 1. REMOVED AND INSTALLED NEW FRAME IAW SRM 51-40-02 AND DWG 143N1024. MAJOR REPAIR.