As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RT CREASE BEAM ANGLE BETWEEN STA 940-980 RBL 64 HAS TWO AREAS OF DAMAGE. BLENDED AREA IAW SRM 51-10-02 CHECKED LIMITS. ORIGINAL MATERIAL .063 REWORK .040 MATERIAL LOSS .023 CREASE BEAM FOUND TO BE OUT OF LIMITS IAW SRM 53-60-13, DETAIL VIII, FIG 101. R & R CREASE BEAM FROM STA 900 -1040 RBL 64 IAW SRM 51-40-02 AND DWG 144N5140. MAJOR REPAIR.