What was found
FLOORBEAM UPPER TEE BS 377 LBL 64 - RBL 10 GOUGED . REMOVED GOUGE, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51 PG 104 DETAIL III. REPAIRED PER SRM 53-00-51, FIG 201, REPAIR 3 . MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM UPPER TEE BS 377 LBL 64 - RBL 10 GOUGED . REMOVED GOUGE, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51 PG 104 DETAIL III. REPAIRED PER SRM 53-00-51, FIG 201, REPAIR 3 . MAJOR REPAIR.