What was found
FWD CABIN -STA 421, X=70 (APPROX) ON REMOVAL OF FLOOR PANEL NR 221GF, FOUND FLOOR SUPPORT CORRODED AND CRACKED. REMOVED IAW SRM 51-31-01, REV 49. NEW FLOOR SUPPORT FABRICATED IAW DWG ABA8303, REV A . FLOOR SUPPORT INSTALLED IAW AMM 20-50-02, REV 72.0. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100, REV 115.