What was found
FRAME 1, STRINGER 25 + 10" FOUND ONE DENT 4.25"X5.5". FOUND WITHIN ALLOWABLE DAMAGE LIMITS IAW SRM 53-11-12. 2. NDI WAS COMPLETED. NO CRACK WAS FOUND REF. TO AB6 NTM PART 6 51-10-07 PAGE 601. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100.