What was found
LOST GREEN SYS HYD FLUID BELOW RED DOT. ECAM WARN GREEN HYD LEVEL LOW PRESSURE AT THAT TIME WAS 950 PSI GREEN PUMPS TURNED OFF AT 940Z, ENGINE SHUTDOWN AT 1030Z. GEAR MANUALLY LOWERED. R&R GREEN SYS HYD TRANSMITTER, ASSOCIATED FILTERS CHANGED, AND POPPETS CHECKED. SERVICED GREEN HYD SYS, RESET PROCEDURE C/W FOR MANUAL GEAR EXT, OPS AND LEAK TEST GOOD.RAN ENGINES IAW JRH CHAPTER 5. OK FOR SERVICE.