What was found
INCOMING DENT AT BS 1390, BETWEEN S-22L TO S-23L. (D-48) EVALUATED DENT-A=1.30, Y=.030, A/Y=43.33. DENT IS LESS THAN 0.50" FROM FRAME FASTENER, AREA FOUND TO BE OUT OF LIMITS IAW SRM 53-00-01, FIG 101, DETAIL III. REPAIRED AREA AT STA 1390 BETWEEN S-22L TO S-23L, IAW SRM 53-00-01, REPAIR 3. THIS REPAIR IS CATEGORY ''B''. MAJOR REPAIR.