What was found
BS 1600, FLOORBEAM HAS PLUGGED HOLES IN UPPER CHORD FROM RBL 62 TO LBL 24, R & R WITH NEW FLOORBEAM FABRICATED IAW DWG146N5107, SHT 1, REV A AND INSTALLED IAW DWG 146N5107 SHT 1. REV A. REPAIR IS MAJOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 1600, FLOORBEAM HAS PLUGGED HOLES IN UPPER CHORD FROM RBL 62 TO LBL 24, R & R WITH NEW FLOORBEAM FABRICATED IAW DWG146N5107, SHT 1, REV A AND INSTALLED IAW DWG 146N5107 SHT 1. REV A. REPAIR IS MAJOR.