What was found
ON CLIMB OUT, AT 29,000 R1 FWD ENTRY DOOR ECAM ALERTED DOOR NOT CLOSED. JUMPSEATER REPORTED DOOR CHIME WAS SOUNDING AND DOOR LOCKS WERE INDICATING "HALF" LOCKED & HALF OPEN. DECENDED TO 10,000 SLOWLY. NO PRESSURE PROBLEMS NOTED. FOUND UPPER HOOKS NOT MAKING CONTACT WITH STOPS. PERFORMED R1 DOOR LOCKING MECHANISM ADJUSTMENT AND TEST IAW AMM 52-10-20-05-01. ADJUSTED UPPER HOOKS TO STOPS IAW AMM 52-10-20-05-01. COMPLETED AMM 52-10-20-05-01 ADJUSTMENT AND TEST FROM STEP C1F.