What was found
R4 DOOR LWR FWD EDGE BENT 6" ALONG EDGE. FOUND OUT OF LIMITS IAW SRM 52-10-01 FIG 101 DETAIL VIII. REPAIRED BEND IN FWD L..E. OF R4 DOOR IAW SRM 52-10-01 FIG 201 REPAIR 7 THIS IS A MAJOR CLASS "B" REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
R4 DOOR LWR FWD EDGE BENT 6" ALONG EDGE. FOUND OUT OF LIMITS IAW SRM 52-10-01 FIG 101 DETAIL VIII. REPAIRED BEND IN FWD L..E. OF R4 DOOR IAW SRM 52-10-01 FIG 201 REPAIR 7 THIS IS A MAJOR CLASS "B" REPAIR.