What was found
CABIN FLOORBEAM BS 377.7, LBL 19 - LBL 24, HAS DAMAGED HOLES. R & R FLOORBEAM, FABRICATED NEW FLOORBEAM IAW DWG 1415123, SHT 1, REV A AND INSTALLED IAW DWG 141N5113, SHT 1 REV F. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOORBEAM BS 377.7, LBL 19 - LBL 24, HAS DAMAGED HOLES. R & R FLOORBEAM, FABRICATED NEW FLOORBEAM IAW DWG 1415123, SHT 1, REV A AND INSTALLED IAW DWG 141N5113, SHT 1 REV F. MAJOR REPAIR.