What was found
MAIN DECK CARGO FLOORBOARD 242UJ HAS 5 AREAS OF CRACKS AT CLEVIS ADAPTER CUTOUT, CRACKRANGE FROM 1" TO 5" LONG. FABRICATED FLOORBOARD IAW DWG SRZ 25-005, REV J.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK CARGO FLOORBOARD 242UJ HAS 5 AREAS OF CRACKS AT CLEVIS ADAPTER CUTOUT, CRACKRANGE FROM 1" TO 5" LONG. FABRICATED FLOORBOARD IAW DWG SRZ 25-005, REV J.