What was found
MAIN DECK CARGO FLOOR SUPPORT TEE CAP UNDER LAVATORY COMPOSITE DRAIN HAS CORROSION AROUND THE SCREW HOLE, APPROX 1 INCH. REMOVED CORRODED FLOOR SUPPORT IAW SRM 51-40-21 PAR 6 & 7. FABRICATED NEW FLOOR SUPPORT IAW DRAWING A53612213. INSTALLED FLOOR SUPPORT IAW SRM 51-40-21 PAR 6 & 7.