What was found
CENTER CARGO DOOR CUT-OUT FORWARD JAMB DOUBLER REPAIR EDGE FOUND BLENDED BY ABOUT .5" AT LONGERON 40RT. R & R IAW SRM 53-00-15, FIG 202, REPAIR 8, REV 50. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100 REV 115.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CENTER CARGO DOOR CUT-OUT FORWARD JAMB DOUBLER REPAIR EDGE FOUND BLENDED BY ABOUT .5" AT LONGERON 40RT. R & R IAW SRM 53-00-15, FIG 202, REPAIR 8, REV 50. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100 REV 115.